skrf.calibration.calibration.OnePort.__init__¶
- OnePort.__init__(measured, ideals, *args, **kwargs)[source]¶
One Port initializer.
If more than three standards are supplied then a least square algorithm is applied.
Notes
See func:Calibration.__init__ for details about automatic standards alignment (aka sloppy_input)
- Parameters
measured (list/dict of
Network
objects) – Raw measurements of the calibration standards. The order must align with the ideals parameter ( or use sloppy_input)ideals (list/dict of
Network
objects) – Predicted ideal response of the calibration standards. The order must align with ideals list ( or use sloppy_input)args – passed to func:Calibration.__init__
kwargs – passed to func:Calibration.__init__
Notes
This uses numpy.linalg.lstsq() for least squares calculation
See also